Prestige
® IAQ and RF ElM
Alerts
and diagnostics
Maintain
close
contact
with
your
customers
by providing
more
comfort
and effi-
ciency
with
alerts
and diagnostics.
Alerts
and reminders
can notify
customers
when
maintenance
or service
is needed,
and display
your
contact
information
to
make
it easy for them
to reach
you. The following
are only a few of many
options.
Check
the thermostat's
on-screen
menus
for more.
Alerts and Faults Log
MENU > INSTALLER OPTIONS > DATALOGS> ALERTS AND FAULTSLOG
The thermostat
saves
the most
recent
25 alerts
or faults,
it records
the date,
time,
alert
status
(snoozed,
dismissed,
recovered),
and diagnostic
information
to help
you identify
and correct
problems.
User
interaction
Log
MENU > INSTALLER OPTIONS > DATA LOGS > USER INTERACTION LOG
Check
this log to find
out if a problem
was caused
by an accidental
user
error.
The log shows
most
changes
made
to thermostat
settings,
by time
and date,
and
describes
what
change
was
made.
The thermostat
records
the most
recent
250 changes.
You can quickly
search
them
by date
and time,
or by function.
This
feature
can
be turned
off if necessary,
so that
no user
interactions
are recorded.
Examples:
*
[date,
time]
Heat temperature
set to 80 ° F
*
[date,
time]
System
mode
set to Off
*
[date,
time]
installer
setup
changed
--
heating
equipment
type
Delta T Diagnostics
MENU > INSTALLER OPTIONS > SETUP DIAGNOSTICS
if a discharge
and return
air sensor
is installed,
the thermostat
can track
system
performance
over
time.
it measures
this as "Delta
T."
This can tell you if the system
is performing
above
or below
expected
standards
which
would
normally
go unnoticed,
and may cause
unnecessary
energy
use. it
can also detect
and warn
about
problems
early,
before
heating
or cooling
equipment
fails.
The thermostat
will measure
and record
Delta
T of the system
for each
stage
you test.
This
information
can be used
to set the proper
Delta
T fault
limits
of the
system.
When
the system
operates
outside
those
limits
multiple
times,
a fault
is
recorded
in the log. if configured
to do so, the system
will then
display
an alert
to
the homeowner.
Delta T Fault Sensitivityis adjustable in the installer Setup (ISU 13180)
Delta T diagnosticsis only for non-zonedforced air systems.