THX9321/9421 Prestige _ IAQ and RF ElM
Heat
pump
with outdoor
temperature
lockouts
Outdoor
temperature
lockouts
are optional.
See installer
Setup
options
(ISU 3120).
Backup
heat allowed
to run with heat pump (see tablebelow)
Hea t pump only
.
!
Heat pump With backUP heat aS needed
I
_=IP = === Backup heat lockout
_=IP==== Compressor
lockout
No backup heat unless indoortemperature drops to selected Backup Heat Differentialsetting, or Backup Heat
UpstageTimer expires.Heat pump stays ON when backup heat turns on.
Backup
heat NOT allowed
to run with heat pump
Heat pump only
Heat
pump or backup heat operates *
Seetablebelow)
Backup
heat lockout
Compressor
lockout
No backup heat unless indoortemperature drops to selected Backup Heat Differentialsetting, or Backup
HeatUpstage Timer expires.Heat pump turns OFF when backup heat turns on.
Heat
pump
and
backup
heat
operation
Backup
Heat Type
Backup
Heat Operation
Backup
Heat Fan Operation
Electric forced air
Allowed to run with heat pump
Thermostat
controls fan
Gas or oil forced air
NOT allowed to run with heat pump
Equipment controls fan
Hot water radiant heat
Allowed to run with heat pump
[n/a]
Hot water fan coil
Selectable in installer setup
Thermostat
controls fan
Other
Selectable in installer setup
Selectable in installer setup
19
69-2490--03

Hide quick links: