2.3.7 Speaker
Before disassembling or reassembling, be sure to refer to "1. Before Disassembling or Reas-
sembling."
(1)
Remove the PBA unit. (Refer to "2.1.4 Slide Cover.")
(2)
Remove the NCU PBA (Line 1). (Refer to "2.3.4 NCU PBA (Line 1 and Line 2).")
(3)
Remove the connector from CN5 on the main PBA.
(4)
Remove the two screws from the speaker, and remove the speaker.
(5)
Reassemble the components in the reverse order of disassembly.
NOTE: After reassembling, turn the power switch ON, open and close the scanner
cover assembly. Press the numeric keypad, the [STOP] key, etc. to confirm
that the buzzer sound is normally generated.
DP120F/DP125F Removal/Replacement
CN5
Fig. 8-2-61
Speaker
8-48
08-02-61
March 2000 © TOSHIBA TEC