3.6.1
Interface Box Connections
The following figure is a detailed illustration of the In-ceiling Interface box.
Fig. 3.9 In-ceiling Interface Box
The following table summarizes the pin connectors and their function:
No.
P103 Alarms In
P102 Alarms Out
P104 Analog Relay
P105 Data In/Out
P101 24 VAC
J102
J101
Table 3.1 Interface Box Wire Terminals
WARNING! 24 VAC Class II power supply only.
!
Bosch Security Systems, Inc.
FIBER OPTICS
ETHERNET
OR UTP
VIDEO
DATA IN/OUT
ALARMS
ALARM IN
OUT
Connector
Pin 1
Pin 2
Alarm 1
Alarm 2
Alarm 1
Alarm 2
Relay N.O. Relay
COM
C-
C+
(BiPhase)
(BiPhase)
Line
Earth
Video BNC
UTP/Ethernet
Installation Manual
Installing the In-Ceiling Mount | en
DOME
POWER
COAX
VIDEO
ANALOG IN
RELAY
Pin 3
Pin 4
Alarm 3
Alarm 4
Alarm 3
GND
Relay
Earth
N.C.
Earth
RXD (+)
Ground
(RS-232/485)
Neutral
Connector Input
Connector Input
Pin 5
Pin 6
Pin 7
GND
Alarm 1
Alarm 2 Ground
TXD (-)
Signal
(RS-232/485)
Ground
F01U010921 | 1.0 | 2006.10