8
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts
5.
Attach the supplied 6-pin Control Data I/O Plug to the incoming control wires. See con-
nector P106 in Table 1.1 on page 9 for wire connections. This step is not required with
Fiber Optic models, since control passes through the fiber optic cable.
NOTICE! If "daisy chaining" a series of AutoDomes, a terminating resistor is required in the
last dome of the series. The Bosch Power Supply Box is supplied with a 110 Ω terminating
resistor located between the biphase terminals C- and C+ (pins 1 and 2) of the P106 control
i
connector. Remove the resistor from all but the last AutoDome power box. The maximum
number of AutoDomes that can be daisy chained is four (4). If using the RS485 protocol for
control, the terminating resistor must be moved from the Biphase C+ and C- (pins 1 and 2)
terminals to the RXD- and TXD+ terminals (pins 4 and 5) of the P106 control connector of the
last AutoDome power box.
6.
Attach a BNC connector to the incoming video coax cable. If using UTP for video or
installing an Ethernet model, attach an RJ45 plug to the incoming UTP cable. If installing
a Fiber Optic model, attach an ST fiber plug to the optic fiber cable. See Chapter 4: Cable
and Wire Standards for the different methods of transmitting video and control protocols,
and wire specifications.
7.
If you are connecting alarm inputs and outputs, attach the supplied 4- and 6-pin Alarm
Connectors with flying lead wires to the appropriate incoming alarm wires.
ALARM OUT 1
ALARM OUT 2
ALARM OUT 3
ALARM GROUND
ALARM IN 3
ALARM IN 4
ALARM IN 5
ALARM IN 6
ALARM IN 7
ALARM GROUND
* Low Voltage TTL (3.3V) can also be used.
Fig. 1.4 Alarm and relay connectors
8.
If you are connecting supervised alarms and relays, attach the supplied 7-pin Relay Con-
nector to the appropriate incoming wires. See Figure 1.4, above, for the wire connec-
tions. See Chapter 5: Alarms and Relay Connections for more details about wiring alarms
and relays.
F01U010921 | 1.0 | 2006.10
WHITE
BROWN
ORANGE
GREEN
WHITE
BROWN
ORANGE
GREEN
YELLOW
BLUE
Installation Manual
AutoDome Modular Camera System
4-PIN
7-PIN RELAY CONNECTOR
ALARM OUT
CONNECTOR
1- N.O.
2- COM
3- N.C.
4- EARTH GROUND
5- ANALOG ALARM 1
6- ANALOG ALARM 2
6-PIN
7- GROUND
ALARM IN
CONNECTOR
Bosch Security Systems, Inc.