Wire the Interface Box

The Interface Box can be wired through the top or side. Use the supplied rubber plug to seal
the hole which will not be used to route wires.
Fig. 3.7 Interface Box Connections
After routing all video, control, power, and alarm wires:
1.
Attach a 3/4-inch NPS (20-mm) conduit fitting to the hole in which you bring in the wires.
Be sure to thread the inside nut to the conduit fitting.
2.
Route the video, control, power, and alarm wires through the conduit fitting and into the
Interface Box.
3.
Cut and trim the wires allowing for sufficient slack to their respective terminals in the
box.
NOTICE! If installing the dome to a drywall ceiling, allow enough wire to make the
i
connections in the Interface Box below the ceiling. See Figure 3.9 on page 45 for connector
locations and Table 3.1 on page 45 for wire connections.
4.
Attach the video and control data in/out wires to their respective terminals in the Inter-
face Box. See Table 3.1 on page 45 for terminal connections.
5.
If using UTP for video or Ethernet, you must attach an RJ45 connector plug to the incom-
ing UTP cable and connect it to its matting connector J101 in the Interface Box. See
Chapter 4: Cable and Wire Standards for specifications.
6.
Connect the 24 VAC power wires to the P101 connector in the Interface Box.
7.
To connect alarm inputs and outputs, attach the supplied 6-pin Alarms In and the 4-pin
Alarms Out connector plugs with flying leads to the appropriate alarm wires. Then con-
nect the plugs to their mating connectors P103 and P102 in the Interface Box.
ALARM OUT 1
ALARM OUT 2
ALARM OUT 3
ALARM GROUND
ALARM GROUND
Fig. 3.8 Alarm and Relay Connector Plugs
8.
To connect supervised alarms and relays, attach the appropriate wires to their terminals
on the P104 connector on the Pipe Interface Board. See Chapter 5: Alarms and Relay Con-
nections for more details on wiring alarms.
F01U010921 | 1.0 | 2006.10
WHITE
BROWN
ORANGE
GREEN
WHITE
ALARM IN 3
BROWN
ALARM IN 4
ORANGE
ALARM IN 5
GREEN
ALARM IN 6
YELLOW
ALARM IN 7
BLUE
* Low Voltage TTL (3.3V) can also be used.
Installation Manual
AutoDome Modular Camera System
7-PIN RELAY CONNECTOR
4-PIN
ALARM OUT
CONNECTOR
1- N.O.
2- COM
3- N.C.
4- EARTH GROUND
5- ANALOG ALARM 1
6- ANALOG ALARM 2
6-PIN
7- GROUND
ALARM IN
CONNECTOR
Bosch Security Systems, Inc.