Bosch rexroth CytroBox Operating Instructions Manual page 43

Hydraulic power unit
Table of Contents

Advertisement

Description of diagnosis
S-0-0390
P-0-1300
S-0-0095
E2013
B300
B300: oil level of tank
very high
E2013
B301
B301: oil level of tank
very low
E2013
B302
B302: particle content S
very high
E2013
B303
B303: particle content
M very high
E2013
B304
B304: particle content L
very high
E2013
B305
B305: particle content
XL very high
E2013
B306
B306: filter clogging
very high
E2013
B307
B307: oil temperature
very high
E2013
B308
B308: oil temperature
very low
E2013
B309
B309: oxygen content
very high
E2013
B310
B310: relative humidity
very high
E2013
B314
B314: system pressure
very low
Table 37: Warnings
Cause
The monitoring of the oil level
indicates a warning.
P-0-1291 > P-0-1389[72]
The monitoring of the oil level
indicates a warning.
P-0-1291 < P-0-1389[71]
The monitoring of the particle
concentration indicates a
warning.
P-0-1424 > P-0-1389[61]
The monitoring of the particle
concentration indicates a
warning.
P-0-1425 > P-0-1389[62]
The monitoring of the particle
concentration indicates a
warning.
P-0-1426 > P-0-1389[63]
The monitoring of the particle
concentration indicates a
warning.
P-0-1427 > P-0-1389[64]
The monitoring of the filter
contamination indicates a
warning.
(P-0-1273 – S-0-0813)
> P-0-1389[30]
The monitoring of the oil
temperature indicates a warning.
P-0-1280 > P-0-1389[26]
The monitoring of the oil
temperature indicates a warning.
P-0-1280 < P-0-1389[25]
The monitoring of the air
inclusion indicates a warning.
P-0-1270 > P-0-1389[7]
The monitoring of the relative
humidity indicates a warning.
P-0-1272 > P-0-1389[13]
The degassing function should
run (P-0-1270 > P-0-1389[2]) but
the oil system pressure is too
low (S-0-0813 < P-0-1389[3]).
Product information 43/128
Remedy
Check/reduce the oil volume in the tank.
Check the limit value.
Check the sensor output signal.
Check/increase the oil volume in the tank.
Check the limit value.
Check the sensor output signal.
Check the limit value.
Check the sensor output signal.
Change the oil.
Check the limit value.
Check the sensor output signal.
Change the oil.
Check the limit value.
Check the sensor output signal.
Change the oil.
Check the limit value.
Check the sensor output signal.
Change the oil.
Check the limit value.
Check the sensor output signal.
Replace the filter element of the pressure
filter.
Check the limit value.
Check the sensor output signal.
Reduce the current load.
Check the oil cooling pump.
Check the water cooling unit.
Check the limit value.
Check the sensor output signal.
Heat the oil.
Check the limit value.
Check the sensor output signal.
Check the degassing function.
Reduce the required flow.
Check the limit value.
Check the sensor output signal.
Check the drainage function.
Reduce the required flow.
Check the limit values.
Perform a pressure control with a higher
command value.
Check the sensor output signal.
CytroBox, RE 51057-B/11.19, Bosch Rexroth AG

Advertisement

Table of Contents
loading