Description of diagnosis
S-0-0390
P-0-1300
S-0-0095
E2013
B300
B300: oil level of tank
very high
E2013
B301
B301: oil level of tank
very low
E2013
B302
B302: particle content S
very high
E2013
B303
B303: particle content
M very high
E2013
B304
B304: particle content L
very high
E2013
B305
B305: particle content
XL very high
E2013
B306
B306: filter clogging
very high
E2013
B307
B307: oil temperature
very high
E2013
B308
B308: oil temperature
very low
E2013
B309
B309: oxygen content
very high
E2013
B310
B310: relative humidity
very high
E2013
B314
B314: system pressure
very low
Table 37: Warnings
Cause
The monitoring of the oil level
indicates a warning.
P-0-1291 > P-0-1389[72]
The monitoring of the oil level
indicates a warning.
P-0-1291 < P-0-1389[71]
The monitoring of the particle
concentration indicates a
warning.
P-0-1424 > P-0-1389[61]
The monitoring of the particle
concentration indicates a
warning.
P-0-1425 > P-0-1389[62]
The monitoring of the particle
concentration indicates a
warning.
P-0-1426 > P-0-1389[63]
The monitoring of the particle
concentration indicates a
warning.
P-0-1427 > P-0-1389[64]
The monitoring of the filter
contamination indicates a
warning.
(P-0-1273 – S-0-0813)
> P-0-1389[30]
The monitoring of the oil
temperature indicates a warning.
P-0-1280 > P-0-1389[26]
The monitoring of the oil
temperature indicates a warning.
P-0-1280 < P-0-1389[25]
The monitoring of the air
inclusion indicates a warning.
P-0-1270 > P-0-1389[7]
The monitoring of the relative
humidity indicates a warning.
P-0-1272 > P-0-1389[13]
The degassing function should
run (P-0-1270 > P-0-1389[2]) but
the oil system pressure is too
low (S-0-0813 < P-0-1389[3]).
Product information 43/128
Remedy
▶
Check/reduce the oil volume in the tank.
▶
Check the limit value.
▶
Check the sensor output signal.
▶
Check/increase the oil volume in the tank.
▶
Check the limit value.
▶
Check the sensor output signal.
▶
Check the limit value.
▶
Check the sensor output signal.
▶
Change the oil.
▶
Check the limit value.
▶
Check the sensor output signal.
▶
Change the oil.
▶
Check the limit value.
▶
Check the sensor output signal.
▶
Change the oil.
▶
Check the limit value.
▶
Check the sensor output signal.
▶
Change the oil.
▶
Check the limit value.
▶
Check the sensor output signal.
▶
Replace the filter element of the pressure
filter.
▶
Check the limit value.
▶
Check the sensor output signal.
▶
Reduce the current load.
▶
Check the oil cooling pump.
▶
Check the water cooling unit.
▶
Check the limit value.
▶
Check the sensor output signal.
▶
Heat the oil.
▶
Check the limit value.
▶
Check the sensor output signal.
▶
Check the degassing function.
▶
Reduce the required flow.
▶
Check the limit value.
▶
Check the sensor output signal.
▶
Check the drainage function.
▶
Reduce the required flow.
▶
Check the limit values.
▶
Perform a pressure control with a higher
command value.
▶
Check the sensor output signal.
CytroBox, RE 51057-B/11.19, Bosch Rexroth AG