Bosch rexroth CytroBox Operating Instructions Manual page 34

Hydraulic power unit
Table of Contents

Advertisement

34/128 Product information
Dissolved air inclusion
Relative humidity
Leakage temperature
Fluid detection
Bosch Rexroth AG, CytroBox, RE 51057-B/11.19
The monitoring of the dissolved air inclusion is active if a measured value via an
I/O link sensor is present. The monitoring is based on a cycle time of 200 ms.
Table 19: Dissolved air inclusion monitoring
Message
Threshold value
[mbar]
Warning
P-0-1389[7]
Error
P-0-1389[8]
The monitoring of the relative humidity is active if a measured value via an
I/O link sensor is present. The monitoring is based on a cycle time of 200 ms.
Table 20: Relative humidity monitoring
Message
Threshold value
[%]
Warning
P-0-1389[13]
Error
P-0-1389[14]
The monitoring of the leakage temperature is active if a measured value via an I/O
link sensor is present. The monitoring is based on a cycle time of 200 ms.
Table 21: Leakage temperature monitoring
Message
Threshold value
[°C]
Warning
P-0-1389[47]
Error
P-0-1389[48]
The fluid detection is active if a measured value via an I/O link sensor is present.
A filling level sensor detects whether fluids are present in the drip pan and whether
it is oil, water or a mixture. The monitoring is based on a cycle time of 200 ms.
Table 22: Fluid detection
Message
Threshold value
P-0-1389[42]
Warning Oil
Warning Mixture
P-0-1389[43]
Warning Water
P-0-1389[44]
Debouncing
time [ms]
P-0-1389[9]
Debouncing
time [ms]
P-0-1389[15]
Debouncing
time [ms]
P-0-1389[46]
Debouncing
[%]
time [ms]
P-0-1389[41]
Diagnostic
Bit in status word
number
(P-0-1412/P-0-1413)
B309
9
D309
Diagnostic
Bit in status word
number
(P-0-1412/P-0-1413)
B310
10
D310
Diagnostic
Bit in status word
number
(P-0-1412/P-0-1413)
B319
12
D319
Diagnostic
Bit in status word
number
(P-0-1412/P-0-1413)
B329
-
B330
B331

Advertisement