Advanced Settings Guide
1.5 System Settings
This section allows the user to change settings related to the HVAC system in their
building. To access these settings, select menu, and choose "System Settings".
1.5.1 Fan Settings
This section allows the user to select one of three available Fan modes. Auto, On
and Circulation.
Default: Auto
1.
Main Menu
2.
System Settings
3.
Mode
4.
Fan
1.5.1.1 Auto
In this mode the fan will only run during heating or cooling operation.
1.5.1.2 On
In this mode the fan will be continuously on, even if the system mode has been set
to Off .
Figure 27
1.5.1.3 Circulation
This feature gives the user the option to circulate air within the conditioned space.
The fan will cycle On and Off depending on the On time and Off time specifi ed in the
setup page. User can also choose to set a schedule during which the fan will cycle.
If the user chooses no schedule the Fan will continuously cycle.
Figure 28
1 0 |
1.5.2 Humidity Control
This feature allows a user with a properly installed and wired humidifi er accessory
to choose how the system controls humidity and set the relative humidity set point.
Selecting No disables the humidity control function.
Options: Yes/No; 30% to 90%
Default: No; 50%
1.
Main Menu
2.
System Settings
3.
Mode
4.
Select Accessory
5.
Select Enable Automatic Humidity control
Use the Up and Down keys to select Humidity Level.
Figure 29
1.5.3 Select Degree C or F
This feature establishes the unit for temperature.
Options: °F or °C
Default: °F
1.
Main Menu
2.
System Settings
3.
Temperature
4.
Unit
Figure 30
Bosch Connected Control BCC100 Thermostat (01.2022)