TRANSPORTATION AND INSTALLATION MANUAL
To move the Z stroke range into the range from 0 to 75 mm, move the fixing
position of the lower limit mechanical stopper 75 mm upward according to the
procedure in 2).
4)
Reinstall the arm 2 cover. Install the arm 2 cover with 10 truss head screw (M3 x
6) and 4 socket head cap screws (M3 x 10) using the recommended tightening
torque.
M3 x 6 10 pcs.
Fig. 2.24 Reinstalling the Arm 2 cover
STE 85389