Data Monitor - Panasonic FP2-PP2T Technical Manual

Fp2 positioning unit (interpolation), programmable controller
Table of Contents

Advertisement

7.15 Data Monitor

The internal data of the positioning unit can be monitored.
Make the connection between a PC and PLC, and configure the settings. Then, select [Online] 
[Data Monitor] in the menu bar. The following dialog is shown.
Axis [Group]
Synchronous group
Synchronous mode
Synchronous condition
Active table number
Auxiliary output code
Current value(pulse)
Current value after unit
conversion
Pulse input value
Deviation
State of axis
Error code
Error clear
Warning code
Warning clear
Help
Close
Note:
If a recoverable error occurred in the positioning unit, click [Error Clear] to clear the error.
If a warning occurred in the positioning unit, click [Warning Clear] to clear the warning.
7-30
The axis No. and group names to be monitored.
Synchronous group name and master/slave axis type
The operation mode of synchronous operation
Synchronous/Asynchronous condition
The table number that the positioning data is being executed or has
completed.
Auxiliary output code
The current value of the positioning unit
The current value of the positioning unit after the unit conversion
Monitor the pulse value to be input.
Monitor the deviation value when activating the automatic difference
behavior function.
The operating states of axes or error and warning occurrences.
The latest error code when an error occurred.
Clear the error by clicking this button, when an error occurred.
Indicate the latest warning code when a warning occurs.
Clear the warning by clicking this button, when a warning occurred.
Indicate the help regarding this function.
Close this dialog.