Changing pulse input values
The pulse input value that has been input can be changed to an arbitrary value when setting the pulse
input purpose to the feedback pulse.
The following area is used for changing the pulse input value.
[Pulse count control area]
Offset
Bank
Name
address
Pulse count value
241H
change request flag
00H
248H
Pulse input changed
value of axis 1
249H
24AH
Pulse input changed
value of axis 2
24BH
24CH
Pulse input changed
value of axis 3
24DH
24EH
Pulse input changed
value of axis 4
24FH
Reference: <17.4.11 Pulse Count Control Area>

13.6.4 Function of High-speed Counter

Setting the pulse input purpose to "High-speed counter" enables the pulse input to be used as an
external counter.
Control of pulse input
On the positioning unit, when setting the pulse input purpose to "High-speed counter", the count of pulse
input value can be arbitrarily stopped. When the count of pulse input value stops, the current pulse input
value is held.
The following area is used to specify to disable/enable the count of pulse input.
[Pulse count control area]
Offset
Bank
Name
address
Pulse count enable
00H
240H
flag
Reference: <17.4.11 Pulse Count Control Area>
Descriptions
When turns the corresponding bits for each axis from 0 to 1, the pulse
input value will be changed to the specified pulse count changed
value.
This flag is an edge trigger. It should be always turned to 1 from 0
when changing the value.
Set the pulse input value of axis 1 to be changed.
Set the pulse input value of axis 2 to be changed.
Set the pulse input value of axis 3 to be changed.
Set the pulse input value of axis 4 to be changed.
Descriptions
When the corresponding bits for each axis is 0, the count of pulse input
value is performed.