7.14.2 Downloading Setting Data to Positioning Unit

Transfer the setting parameters and positioning data to the positioning unit.
1. Make the connection between a PC and PLC, and configure the settings. Then, select [File] 
[Download to Unit] in the menu bar, or click the [Download to Unit] icon in the toolbar.
The dialog is shown as below.
Axis information +
Parameter setting data
Axis information +
Parameter setting data +
Positioning setting data
Positioning setting data range
All
Table number range
OK
Cancel
2. Click [OK] to start the download to the positioning unit. The time required for the download
depends on the range of the positioning setting data.
Note:
To execute the download, previously determine the target positioning unit by the communication settings
and selecting the slot number.
7-28
Select this to download axis information and parameter only.
Select this to download all setting data. The range of the positioning
data to download can be specified.
Download all setting data.
Download the positioning data in the specified range.
Start downloading with the selected settings.
Stop downloading.