3.5 Connection of Deviation Counter Clear Output Signal
(for servo motor)
This is an example showing connection of the counter clear input to the servo motor driver. An external
power supply (+5 V DC to +24 V DC) must be provided for the connection.
Note:
Always use twisted - pair cables for wiring.
The Current which can be conducted as the deviation counter clear output signal is 10 mA max.
If 10 mA is exceeded, resistance should be added.