Siemens SINUMERIK 840D sl Function Manual page 422

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Detailed description
2.3 Setpoint /actual-value system
Types of actual-value acquisition
The used edcoder type must be defined through the following machine data:
MD30240 $MA_ENC_TYPE (type of actual-value acquisition (actual position value))
Simulation axes
The speed control loop of an axis can be simulated for test purposes.
The axis "traverses" with a following error, similar to a real axis.
A simulation axis is defined by setting the two following machine data to "0":
MD30130 $MA_CTRLOUT_TYPE[n] (output value of setpoint)
MD30240 $MA_ENC_TYPE[n] (type of actual-value acquisition)
As soon as the standard machine data have been loaded, the axes become simulation axes.
The setpoint and actual value can be set to the reference point value with reference point
approach.
The machine data:
MD30350 $MA_SIMU_AX_VDI_OUTPUT (output of axis signals with simulation axes)
can be used to define whether the axis-specific interface signals are to be output on the PLC
during the simulation.
Actual-value correction
If actual-value corrections performed by the NC on the encoder selected for position control
do not influence the actual value of another encoder defined in the same axis, then this
encoder is to be declared as "independent" via the following machine data:
MD30242 $MA_ENC_IS_INDEPENDENT
Actual-value corrections include the following:
• Modulo treatment
• Reference point approach
• Measuring system comparison
• PRESET
34
Basic logic functions: Velocities, Setpoint/Actual Value Systems, Closed-Loop Control (G2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all

Table of Contents