Number
Identifier: $SA_
43500
FIXED_STOP_SWITCH
43510
FIXED_STOP_WINDOW
43520
FIXED_STOP_TORQUE
5.3
Signals
5.3.1
Signals to axis/spindle
DB number
Byte.Bit
31, ...
1.1
31, ...
1.2
31, ...
1.3
31, ...
2.1
31, ...
3.1
5.3.2
Signals from axis/spindle
DB number
Byte.Bit
31, ...
62.4
31, ...
62.5
50
Description
Acknowledge fixed stop reached
Sensor for fixed stop
Axis/spindle disable
Controller enable
Enable travel to fixed stop
Description
Activate travel to fixed stop
Fixed stop reached
Description
Selection of travel to fixed stop
Clamping torque when traveling to fixed stop
extended to a torque greater than 100%
Fixed stop monitoring window