Siemens SINUMERIK 840D sl Function Manual page 712

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Detailed description
2.9 Program control
Constraints
If the length of a display block configured in MD28400 $MC_MM_ABSBLOCK is exceeded,
this display block is truncated accordingly. This is represented by string "..." at the end of the
block.
For preprocessed cycles (MD10700 $MN_PREPROCESSING_LEVEL > 1), the display block
contains only axis positions.
Additional boundary conditions for the basic block display:
• Modal synchronized action blocks with absolute values are
• The basic block display is deactivated during block search with or without computation.
• Polar coordinate programming is not shown in Cartesian system.
Radius / diameter values
Diameter values shown in the basic block display and position display may be needed as a
radius for internal calculation. These values for measurements in radius/diameter according
to G code group 29 can be manipulated using the following options:
• G code DIAMCYCOF (expansion of channel-specific diameter programming)
• G code DIACYCOFA[AX] (axis-specific diameter programming)
• MD27100 $MC_ABSBLOCK_FUNCTION_MASK
Bit0 = 1
154
not taken into account.
This G code deactivates the channel-specific diameter programming during the cycle
execution. In this way, computations in the cycle can always be done in the radius. The
position display and the basic block display are continued according to the state of the
diameter programming before DIAMCYCOF.
In the basic block display, the last displayed value is retained.
This G code deactivates the axis-specific diameter programming during the cycle
execution. In this way, computations in the cycle can always be done in the radius. In the
position display and in the basic block display, this continues according to the state of the
diameter programming before DIACYCOFA[AX].
In the basic block display, the last displayed value is retained.
Transverse axis setpoints are always shown as diameter values in the
basic block display.
Basic logic functions: Mode group, channel, program operation, reset response (K1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all

Table of Contents