Siemens SINUMERIK 840D sl Function Manual page 136

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Examples
4.2 Protection zones
$SN_PA_PLUS_LIM[0]
$SN_PA_MINUS_LIM[0]
$SN_PA_CONT_NUM[0]
$SN_PA_CONT_TYP[0,0]
$SN_PA_CONT_TYP[0,1]
$SN_PA_CONT_TYP[0,2]
$SN_PA_CONT_TYP[0,3]
$SN_PA_CONT_TYP[0,4]
$SN_PA_CONT_TYP[0,5]
$SN_PA_CONT_TYP[0,6]
$SN_PA_CONT_TYP[0,7]
$SN_PA_CONT_TYP[0,8]
$SN_PA_CONT_TYP[0,9]
$SN_PA_CONT_ORD[0,0]
$SN_PA_CONT_ORD[0,1]
$SN_PA_CONT_ORD[0,2]
$SN_PA_CONT_ORD[0,3]
$SN_PA_CONT_ORD[0,4]
$SN_PA_CONT_ORD[0,5]
$SN_PA_CONT_ORD[0,6]
$SN_PA_CONT_ORD[0,7]
$SN_PA_CONT_ORD[0,8]
$SN_PA_CONT_ORD[0,9]
$SN_PA_CONT_ABS[0,0]
$SN_PA_CONT_ABS[0,1]
70
0
; Value of the limit in the positive direction in the 3rd
dimension
0
; Value of the limitation in the negative direction in the 3rd
dimension
4
; Number of valid contour elements
1
; Contour type[i] : 1 = G1 for even,
; Protection zone for spindle chuck, contour element 0
1
; Contour type[i] : 1 = G1 for even,
; Protection zone for spindle chuck, contour element 1
1
; Contour type[i] : 1 = G1 for even,
; Protection zone for spindle chuck, contour element 2
1
; Contour type[i] : 1 = G1 for even,
; Protection zone for spindle chuck, contour element 3
0
; Contour type[i] : 0 = not defined,
; Protection zone for spindle chuck, contour element 4
0
; Contour type[i] : 0 = not defined,
; Protection zone for spindle chuck, contour element 5
0
; Contour type[i] : 0 = not defined,
; Protection zone for spindle chuck, contour element 6
0
; Contour type[i] : 0 = not defined,
; Protection zone for spindle chuck, contour element 7
0
; Contour type[i] : 0 = not defined,
; Protection zone for spindle chuck, contour element 8
0
; Contour type[i] : 0 = not defined,
; Protection zone for spindle chuck, contour element 9
-100
; Endpoint of contour[i], ordinate value
; Protection zone for spindle chuck, contour element 0
-100
; Endpoint of contour[i], ordinate value
; Protection zone for spindle chuck, contour element 1
100
; Endpoint of contour[i], ordinate value
; Protection zone for spindle chuck, contour element 2
100
; Endpoint of contour[i], ordinate value
; Protection zone for spindle chuck, contour element 3
0
; Endpoint of contour[i], ordinate value
; Protection zone for spindle chuck, contour element 4
0
; Endpoint of contour[i], ordinate value
; Protection zone for spindle chuck, contour element 5
0
; Endpoint of contour[i], ordinate value
; Protection zone for spindle chuck, contour element 6
0
; Endpoint of contour[i], ordinate value
; Protection zone for spindle chuck, contour element 7
0
; Endpoint of contour[i], ordinate value
; Protection zone for spindle chuck, contour element 8
0
; Endpoint of contour[i], ordinate value
; Protection zone for spindle chuck, contour element 9
0
; Endpoint of contour[i], abscissa value
; Protection zone for spindle chuck, contour element 0
110
; Endpoint of contour[i], abscissa value
; Protection zone for spindle chuck, contour element 1
Basic logic functions: Axis monitoring, protection zones (A3)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0