Siemens SINUMERIK 840D sl Function Manual page 696

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Detailed description
2.7 Program operation mode
The following diagram illustrates which routines are used:
User SW
_N_ASUP_SPF
Figure 2-14
Replacing system ASUBs with user routines
Installation of user system ASUBs
One routine named _N_ASUP_SPF can be loaded in directory _N_CUS_DIR. You must
implement the actions desired by the user for:
RET for Value 1 in MD11610
REPOS for Value 2 in MD11610
Reason for activation of an ASUP and its significance
The reason that led to the activation is specified in bit code through the $AC_ASUP system
variable, and can be read in part program and synchronized actions.
Bit
19
18
17
RET
REPOS
1
1
On*): If Bit 9 is set, the branching of machine data depends on
MD20114 $MC_MODESWITCH_MASK (interrpution of MDA through mode change):
Bit 0 set: →RET
Bit 0 not set: →REPOS
138
ASUP_EDITABLE
User
RET
User
REPOS
16
15
14
13
1
1
1
1
1
NCK system SW
System
ASUB
RET
0
1
System
ASUB
RET
2
Value stored in MD 11610
12
11
10
9
8
1
*
1
1
*
Basic logic functions: Mode group, channel, program operation, reset response (K1)
System
ASUB
REPOS
System
ASUB
REPOS
7
6
5
4
1
1
1
1
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
3
2
1
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all