Software; Remote Connect; Remote Connect With Customer Control; Remote Connect With Callback Verification - Bosch AMAX panel 2000 Installation Manual

Hide thumbs Also See for AMAX panel 2000:
Table of Contents

Advertisement

AMAX panel 2000 / AMAX panel 2000 EN
Anytime the 24-Hour zone is violated.
Anytime the tamper is violated.
Keypad alarm operation.
When system is armed and the armed zone, which is not bypassed, is violated.
After the entry delay time runs out, if the system has not been disarmed and the zone has
been violated, an alarm occurred.
Alarm performance:
Send the report to the configured destinations of the control panel system.
Flashing the violated zone indicators to indicate the ALARM status.
Activate the related output according to the output configuration.
Activate the keypad buzzer follow the output status by setting Location 370.
Record the event in history.
7.4

Software

You can program or control the AMAX panel 2000 / AMAX panel 2000 EN remotely using a PC
and remote programming software. This software allows you to change your customer's
control panel without leaving your office.
7.4.1

Remote Connect

The remote connect feature allows you to establish a connection through the telephone
network from your computer to the AMAX panel 2000 / AMAX panel 2000 EN. This software
allows you to offer faster service to your clients.
7.4.2

Remote Connect with Customer Control

If you want to configure the control panel to establish a remote connection, it is possible only
when the client initiates it through the remote keypad. Program the following information:
The control panel is now set ready for the client to control and establish a remote connection.
To dial the remote computer:
Enter your code + [7] and press [#].
When the command operates, the control panel calls the remote computer telephone with the
remote control software open and is set to Waiting for an Incoming Call.
After uploading /downloading the data, the control panel exits from the remote program and
returns to the disarmed state.
7.4.3

Remote Connect with Callback Verification

The control panel receives the call. As the ring count set in Location 152 is reached, it picks
up the call and attempts to establish data connection with the remote computer.
NOTICE!
If the connection cannot be established, the control panel regards it as a remote arming
command and accepts it.
The control panel hangs up the telephone.
The control panel initiates a callback.
The remote computer is now operating remote programming software and is set to Waiting
for an Incoming Call.
After uploading /downloading the data, the control panel exits from callback and returns to
the disarmed state.
Bosch Sicherheitssysteme GmbH
Program the Call Back Telephone Number in Location 154 - 169 .
Start using remote program in Location 153.