AMAX panel 2000 / AMAX panel 2000 EN
9
Technical Data
9.1
Specification
Panel
Enclosure :
Dimensions (HxWxD):
Weight:
Environmental Considerations :
Relative Humidity:
Operating Temperature:
Supervised Zones:
Onboard:
Z1 - Z8 COM
P8 Tamper
Programmable Outputs (PO):
Onboard:
OC 1
OC 2
OC 3
Auxiliary module
(DX3010):
Relay 1-8
Cable requirements:
Number of...
Users:
Key Fobs:
Events:
Pin Code variations
DX 3010:
B 420 or DX 4020 or DX
4020 G
Keypads:
Power:
Power Supply Type:
Transformer:
AC Input:
DC Output:
Bosch Sicherheitssysteme GmbH
–
260mm x 280mm x 83,5mm
–
1950g
–
10%-95%
–
-10°C - +55°C
–
8 Single or dual end-of-line (EOL 2,2KΩ) tamper point
support
–
Enclosure tamper input (does not reduce point capacity)
–
supervised output max 500mA
–
supervised output max 500mA
–
max 100mA
–
Contacts rated 5A at 28VDC
–
Unshielded and shielded 0,6-0,8mm
–
16 (8 + 8Keyfob)
–
8
–
254 history events, stamped with time and date
–
254 EN history events, stamped with time and date
–
10000
–
1
–
1
–
2
–
A
–
230V Input/18VAC 20VA Fuse=500mA
–
AC Input Voltage: 195 VAC to 253 VAC
–
Line Voltage Frequency: 50 Hz
–
maximum current for all components 1100mA
–
maximum current for all components 550mA (recharge Batt
80% in 72h)
Installation Manual
Technical Data | en
75