Siemens M20 Terminal Technical Description page 91

Cellular engine
Hide thumbs Also See for M20 Terminal:
Table of Contents

Advertisement

Siemens Information and Communication Products
AT+VGT
Transmit gain selection of microphone
Test command
Response
AT+VGT=?
+VGT: (list of supported <n>) OK
Parameter
see set command
Read command
Response
AT+VGT?
+VGT: <n> OK
:
Note
Parameter
see set command
Set command
Response
AT+VGT=[<n>]
TA sets amplification of audio samples sent from the TA to the computer.
OK
Parameter:
<n>
:
Note
Reference
Note
GSM 07.07
Set command works only in audio mode 3.
AT+VIP
Initialize voice parameters
Test command
Response
AT+VIP=?
+VIP: list of supported <n>s OK
Parameter
see set command
Test command
Response
AT+VIP?
+VIP: <n> OK
Parameter
see set command
Set command
Response
AT+VIP=<n>
TA activates the selected audio set.
OK
Parameter
<n>
Reference
Note
GSM 07.07
In mode 1, no audio parameters can be set. The following set commands can be used in mode 3:
+VGR
+VGT
^SNFA
^SNFI
^SNFO
^SNFE
Version 8 dated 15.03.00
this command may only be used with (AT^SNFS=3) audio mode 3.
0 – Automatic gain control
1(0x1)-128(0x80)-255(0xFF)
gain=20*log(n/128)
default value is 128.
Hex input not accepted
1(0x1)
Audio mode 1: standard mode approved for handset V38140-H-X33
3(0x3)
Audio mode 3: customer-specific mode; all audio parameters can be
adjusted by AT commands
AT command interface
A
91

Hide quick links:

Advertisement

Table of Contents
loading