Siemens M20 Terminal Technical Description page 42

Cellular engine
Hide thumbs Also See for M20 Terminal:
Table of Contents

Advertisement

Siemens Information and Communication Products
ATS10
Set disconnect delay after indicating the absence of data carrier
Read command
Response
ATS10?
<n> OK
Set command
Response
AT10=<n>
This parameter setting determines the amount of time that the TA remains connected in absence of
data carrier. If the data carrier is detected before disconnect, the TA remains connected.
OK
Parameter
<n>
Reference
Note
V.25ter
ATS12
Set pause length for Hayes ESC sequence
Read command
Response
ATS12?
<n> OK
Set command
Response
AT12=<n>
This parameter setting determines the length of pause on the start and end of Hayes escape sequence
in. 0.1 sec.
OK
Parameter
<n>
Reference
Note
V.25ter
ATV
Set result code format mode
Set command
Response
ATV[<value>]
This parameter setting determines the contents of the header and trailer transmitted with result co-
des and information responses.
OK
OK
Parameter
<value>
Reference
Note
V.25ter
Version 8 dated 15.03.00
1-15-255 number of tenths of seconds of delay
1-10-255 number of tenths of seconds of pause length
When <value> =0
When <value> =1
0
Information response: <text><CR><LF>
Short result code format: <numeric code><CR>
1
Information response: <CR><LF><text><CR><LF>
Long result code format: <CR><LF><verbose code><CR><LF>
AT command interface