Siemens M20 Terminal Technical Description page 53

Cellular engine
Hide thumbs Also See for M20 Terminal:
Table of Contents

Advertisement

Siemens Information and Communication Products
AT+IPR
Set fixed local rate
Test command
Response
AT+IPR=?
+IPR: (list of supported auto-detectable <rate>s), (list of supported fixed-only <rate>s) OK
Parameter
see set command
Note:
Read command
Response
AT+IPR?
+IPR: <rate> OK
Parameter
see set command
Set command
Response
AT+IPR=<rate>
This parameter setting determines the data rate of the TA on the serial interface. TA must also accept
the following minimum rates from TE in command mode only: 1200 bit/s and 9600 bit/s. The rate
of command takes effect following the issue of any result code associated with the current command
line.
OK
Parameter
<rate>
Reference
Note
V.25ter
M20 has standard 19200 baud connection. No autobauding available.There has to be a pause of at
least 300ms after the OK, before the next command is entered.
Version 8 dated 15.03.00
)1) M20 has no Autobauding, therefore only the second list is presented.
2) When using AT+IPR=x(CR) alone a delay of 300ms needed before next command (AT...)
is sent. Otherwise "OK" response may be corrupted.
3)
No
restrictions
of
AT&Fs0=1+ipr=9600&W+cbst=7,0,1)
baud rate per second
300
1200
2400
4800
9600
19200
28800
38400
57600
use
of
"+IPR=x"
within
AT command interface
a
command
string.
(e.g.:
A
53