APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 3 of 38)
ADDR
REGISTER NAME
1575
...Repeated for module number 10
1579
...Repeated for module number 11
157D
...Repeated for module number 12
1581
...Repeated for module number 13
1585
...Repeated for module number 14
1589
...Repeated for module number 15
158D
...Repeated for module number 16
Direct I/O States (Read Only)
15A0
Direct Input x 1 State
15A1
Direct Input x 2 State
Ethernet Fibre Channel Status (Read/Write)
1610
Ethernet Primary Fibre Channel Status
1611
Ethernet Secondary Fibre Channel Status
Data Logger Actuals (Read Only)
1618
Data Logger Channel Count
1619
Time of oldest available samples
161B
Time of newest available samples
161D
Data Logger Duration
L90 Channel Status (Read Only)
1620
L90 Channel 1 Status
1621
L90 Channel 1 Number of lost packets
1622
Channel 1 Local Loopback Status
1623
Channel 1 Remote Loopback Status
1626
L90 Channel 1 Loop Delay
1627
L90 Channel 2 Status
1628
L90 Channel 2 Number of lost packets
1629
Channel 2 Local Loopback Status
162A
Channel 2 Remote Loopback Status
162B
L90 Network Status
162D
L90 Channel 2 Loop Delay
162E
Channel PFLL Status
L90 Channel Status (Read/Write Command)
162F
L90 Channel Status Clear
Source Current (Read Only) (6 modules)
1800
Phase A Current RMS
1802
Phase B Current RMS
1804
Phase C Current RMS
1806
Neutral Current RMS
1808
Phase A Current Magnitude
180A
Phase A Current Angle
180B
Phase B Current Magnitude
180D
Phase B Current Angle
180E
Phase C Current Magnitude
1810
Phase C Current Angle
1811
Neutral Current Magnitude
1813
Neutral Current Angle
1814
Ground Current RMS
1816
Ground Current Magnitude
1818
Ground Current Angle
1819
Zero Sequence Current Magnitude
181B
Zero Sequence Current Angle
181C
Positive Sequence Current Magnitude
181E
Positive Sequence Current Angle
181F
Negative Sequence Current Magnitude
GE Power Management
RANGE
0 to 1
0 to 1
0 to 2
0 to 2
0 to 16
0 to 4294967295
0 to 4294967295
0 to 999.9
0 to 2
0 to 65535
0 to 2
0 to 2
0 to 200
0 to 2
0 to 65535
0 to 2
0 to 2
0 to 2
0 to 200
0 to 2
0 to 1
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
L90 Line Differential Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F108
---
1
F108
---
1
F134
---
1
F134
CHNL
1
F001
seconds
1
F050
seconds
1
F050
DAYS
0.1
F001
---
1
F134
---
1
F001
---
1
F134
---
1
F134
ms
0.1
F001
---
1
F134
---
1
F001
---
1
F134
---
1
F134
---
1
F134
ms
0.1
F001
---
1
F134
---
1
F126
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
DEFAULT
B
0 (Off)
0 (Off)
0 (Fail)
0 (Fail)
0
0
0
0
1 (OK)
0
2 (n/a)
2 (n/a)
0
2 (n/a)
0
2 (n/a)
2 (n/a)
1 (OK)
0
1 (OK)
0 (No)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0