Nur für den internen Gebrauch
3.3.15

SLMAE8, SLMAE (SLMAE200)

NOTE
>
Danger of damage to property due to surge voltage. The required lightning protec-
tion measures must be taken for this board, see Section 2.1.2, "Lightning Protec-
tion".
Introduction
The SLMAE8 and SLMAE [SLMAE200] boards (Subscriber Line Module Analog Enhanced)
provide analog T/R interfaces for use in HiPath 3800 as of V6.0 SMR-10:
SLMAE8 (S30810-Q2225-X100) = 8 analog T/R interfaces
SLMAE (S30810-Q2225-X200) = 24 analog T/R interfaces
These boards support calling name identification presentation (CLIP).
NOTE
>
External analog extensions may only be connected via the SLMAE board.
For U.S. only: The connection of external analog extensions via OPS signaling (OPS: Off-Pre-
mises-Station) is not supported.
Ring voltage
SLMAE8 and SLMAE boards generate their own ring voltage at 65 V
generator is therefore not required.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
boards.fm
Boards for HiPath 3000
Peripheral boards
. An external ring voltage