Connect the base station to three free interfaces on SLC16N as shown in Figure 3-55. Be care-
ful not to exceed the maximum connection cable lengths (1000 m for 2 x 0.6 mm).
The use of three U
P0/E
HiPath 3550
SLC16N
Splitting
strip
1
MDFU, MDFU-E
Figure 3-55
Base Station Power Supply via Three
Additional UPSC-D power supply via an external power supply unit
If the power supplied by the UPSC-D (HiPath 3550) is insufficient, additional power can be sup-
plied by installing the external power supply (Powerbox PB3000). To do this, connect the DC
port on the PB3000 to the special DC input on the UPSC-D.
As described on the preceding pages, the base stations must be connected to free U
faces. BS3/1 needs one, BS3/2 needs two, and BS3/3 needs three free U
Powerbox PB3000 is also used if an external power supply unit is required for HiPath 3500 or
HiPath 3300 (19-inch housing).
Section 11.4, "Power-Related Capacity Limits" shows which telephone configurations manage
without an additional power supply and which configurations require an additional one.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
interfaces increases the traffic capacity in the base station.
CABLU
Interfaces
P0/E
a
b
Interfaces (not for U.S.)
P0/E
boards.fm
Boards for HiPath 3000
Peripheral boards
BS3/3, BS4 for indoors
2
U
1
P0/E
3
4
U
2
P0/E
5
6
U
3
P0/E
7
P0/E
interfaces.
P0/E
inter-
3-149