Siemens SINUMERIK 840Di Function Manual page 425

Basic machine
Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

The type of fine interpolation can be defined via machine data:
MD33000 $MA_FIPO_TYPE (fine interpolation type).
A differential FIPO not only performs cycle matching but also calculates a mean value
(smoothing) from an IPO cycle.
The cubic FIPO, type 3, supplies the best contour accuracy in addition to the cycle
adaptation.
K
factor
v
To ensure that only low contour deviations occur in continuous-path mode,
a high servo gain factor (K
MD32200 $MA_POSCTRL_GAIN[n]
is required.
However, if the servo gain factor (K
impermissibly high loads on the machine will result.
The maximum permissible servo gain factor (K
• Design and dynamics of the drive
• Machine quality
• Position-control cycle
The servo gain factor (K
[m/min]/[mm]:
Velocities, Setpoint/Actual-Value Systems, Closed-Loop Control (G2)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
(rise time, acceleration and braking capacity)
(elasticity, oscillation damping)
) is defined as follows:
v
Unit of servo gain factor (K
):
v
) is too high, instability, overshoot and possibly
v
) depends on the following:
v
) according to VDI standard
V
Detailed Description
2.4 Closed-loop control
2-51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents