2.3
Starting up hardware configuration of PLC CPUs
2.3
General procedure
STEP 7 is used to define the hardware configuration for a PLC CPU, including the
associated I/O.
The procedure to be followed is shown below:
1. Load tool box to PG/PC
2. Create a new project (File, New, Project)
3. Insert, Hardware, SIMATIC 300 station
4. Select SIMATIC 300 station1 with mouse
5. Open object by right-clicking with the mouse to start the HWConfig
6. Destination system, load to PG, the hardware equipment complement is read back from
7. Configure distributed I/Os
8. Insert PLC basic program
The addresses for the I/O modules can be changed if necessary (permissible only on certain
PLC CPUs, e.g. PLC 3152DP).
As an alternative, the entire hardware configuration can be entered manually (see also
appropriate STEP7 documentation). The notices below must be observed.
STEP7, Version 3
In STEP7 Version 3 and higher, the hardware configuration of the SINUMERIK components
must be defined with the entries in SIMATIC\RACK 300. The install or setup program of the
basic program on the tool box diskettes is required for this purpose.
STEP7 Version 5.1 SP2 and Toolbox 6.03.02
In STEP7 V5.1 SP2 and Toolbox 6.03.02 and higher, the SINUMERIK components are
stored under SIMATIC 300\SINUMERIK. The current hardware expansion for STEP 7 can
also be found under eSupport.
Current path (02/13/2004): sinumerik_software > 840d/810d/fm-nc > patches & fixes > plc >
Hardware_fuer_STEP7 > Hardware up to NCU*.5/CCU3/840Di_MCI2 > V6.5.2.0
NCU
CCU1 810D CPU
CCU2 810D CPU
CCU1 810DE CPU
CCU2 810D CPU
SINUMERIK 810DE Light
CCU1 module
with system software (export)
SINUMERIK 810D CCU2
module with system software
(standard)
Power Line Basic PLC Program (P3)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
the central system
MLFB
6FC5 410-0AA00-0AA0
6FC5 410-0AA01-0AA0
6FC5 410-0AY01-0AA0
6FC5 410-0AX02-0AA0
6FC5 410-0AY00-0AA0
6FC5 410-0AX02-1AA0
2.3 Starting up hardware configuration of PLC CPUs
Comparable
SIMATIC CPU MLFB
included
6ES7 314-1AE01-0AB0
6ES7 314-1AE01-0AB0
6ES7 314-1AE01-0AB0
6ES7 314-1AE01-0AB0
6ES7 314-1AE01-0AB0
6ES7 315-2AF01-0AB0
Detailed description
Selection from STEP7 hardware
catalog
810D/840D with PLC314
810D/840D with PLC314
810D/840D with PLC314
810D/840D with PLC314
810D/840D with PLC314
810D/840D with PLC3152AF01