Siemens SINUMERIK 840Di Function Manual page 622

Basic machine
Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Detailed Description
2.7 Program operation mode
2.7.6
Channel status
Interface representation
The current channel status is displayed in the interface. The PLC can then trigger certain
responses and interlocks configured by the manufacturer depending on the status at the
interface.
The channel status is displayed in all operating modes.
Channel statuses
The following channel statuses are available:
• Interface signal DB21, ... DBX35.7 ("Channel status reset")
• Interface signal DB21, ... DBX35.6 ("Channel status interrupted")
• Interface signal DB21, ... DBX35.5 ("Channel status active")
For a further explanation of the individual signals see Chapter 5.
The effect of commands/signals
The channel status can be modified through the activation of various commands or interface
signals. The following table shows the resulting channel status (assumption: status before
the signal -> channel status active).
"Channel status active" is achieved when a part program or
part program block is executed or when the axes are traversed in JOG mode.
Commands
IS "Reset"
IS "NC Stop"
IS "NC stop at block limit"
IS "NC stop axes and spindles"
IS "Read-in disable"
IS "Feed stop, channelsp."
IS "Feed stop, axissp."
Feed override = 0%
IS "Spindle stop"
M02/M30 in a block
M00/M01 in a block
IS "Single block"
IS "Delete distancetogo"
Auxiliary functions output to PLC but
not yet acknowledged
Wait instruction in program
2-86
Resulting channel status
Reset
X
X
Mode Group, Channel, Program Operation, Reset Response (K1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Interrupted
X
X
X
X
X
Active
X
X
X
X
X
X
X