Siemens SINUMERIK 840D sl Commissioning Manual page 32

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Power on and boot up
5.1 Operating and display elements for run-up
Note
When you turn the start-up switch or operating mode switch, then the status display
indicates the selected number/letters!
LED display
The following LED displays indicate states at the NCU
● RDY (yellow) -> Write/read access to the CF card,
● RUN (green) -> PLC running
● STOP (yellow) -> PLC stopped
● SU/PF (yellow) -> Force PLC active
● SF (red) -> general PLC error, see diagnostic buffer
● DP1 (red) -> Error on PROFIBUS (X126)
● DP2 (red) -> Error on PROFIBUS (X136)
● OPT (red) -> Error on option module
NCK start-up switch
The following switch settings are assigned:
● 0 -> NCK in the operating mode
● 1 -> NCK in the initial clear mode (standard MD)
● 7 -> NCK is not started during run-up
● 8 -> Display IP address for the factory network at X130
PLC mode selector switch
The following switch settings are assigned:
● 0 -> NC in operating mode
● 1 -> NC in operating mode, protected
● 2 -> NC in operating mode
● 3 -> PLC general reset
32
RDY (red) -> Watchdog (no NCK ready),
RDY (green) -> not used with SINUMERIK
– Turn the NCK start-up switch to "8"
– Trigger RESET.
– The individual values of the IP address are displayed as individual digits with points to
separate the individual values. The last digit does not have a point. The IP address is
displayed again after a short delay. In this state, no NCK operation is possible.
Commissioning Manual, 07/2007, 6FC5397-2AP10-3BA0
IBN CNC: NCK, PLC, drive

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120