Optimize the drive.
11.3 Circularity test measurement
Display mode
The following parameter assignments for programming the mode of representation of
measurement results can also be made:
● Display based on mean radius
● Display based on programmed radius
● Scaling of the diagram axes
If the measuring time calculated exceeds the time range that can be displayed from the trace
buffers (maximum measuring time = position controller cycle frequency * 2048), a coarser
sampling rate is used for recording (n * position controller cycle frequency), so that a
complete circle can be displayed.
Figure 11-8
The two drives selected for measurement must describe a circular interpolation (G2/G3) with
the parameters shown in the example via a part program:
Radius=100 mm, F=10000 mm/min
202
Circularity test measurement parameters
Commissioning Manual, 07/2007, 6FC5397-2AP10-3BA0
IBN CNC: NCK, PLC, drive