2-4-5 Time hold

Actual date
Example: 15 o'clock at Day 1
ON
TIME HOLD IN
OFF
ON
TRIG.IN
OFF
ON
MARKING OUT
OFF
ON
READY OUT
OFF
ON
GAP OUT
OFF
Reference
• The time at system startup is held when the laser marker is turned to on with the TIME HOLD ON.
• If the TIME HOLD is set ON, the time is held in spite of switching the file No.
• If the TIME HOLD ON/OFF is switched in short time, each ON/OFF hold time should be more than 2 seconds.

2-4-6 Counter end

READY OUT
TRIG.IN
MARKING OUT
COUNTER END OUT
(CEND 0 to 3)
Item
Time
T1
10ms or more
Reference
• Counter End outputs are kept till the next start of marking.
• Counter End output becomes OFF when shutter is closed.
• Common Counter 4 to 7 have no counter end output function.
• When "Step & Repeat counter at each step" function is set, counter end output is invalid.
Day 1
Marking
with the
time at ON
(3 p.m. at Day 1 )
ON
OFF
ON
T1
OFF
ON
OFF
The end value is marked.
ON
OFF
Remarks
Keep the ON status for 10ms or more.
Marking
with the
time at ON
(3 p.m. at Day 1 )
Re-dating
T1
T1
ME-LP400V-EX-6
Day 2
8 a.m. at Day 2
(Marking with the time
at 8 a.m. at Day 2)
T1
49