⿎ Laser pulse cycle : MPL
[Supported models: LP-V series]
Sets the laser pulse cycle of LP-V series.
• Setting / Readout data of laser pulse cycle
Sub
STX
MPL
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
• Readout request of laser pulse cycle
STX
MPL
R
Data
Name
length
[byte]
Laser pulse cycle
⿎ CW pulse cycle/duty : CWL
[Supported models: LP-W series]
Adjust the laser pulse cycle and duty of LP-W series.
• Setting / Readout data of CW pulse cycle and duty
STX
CWL
S
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
• Readout request of CW pulse cycle and duty
STX
CWL
R
Data
Name
length
[byte]
CW pulse cycle
Duty
130
[Laser pulse cycle]
4-byte
(Check sum)
Delimiter
Description
4
"10.0"–"50.0" [ms]
[CW pulse cycle] [Duty]
7-byte
(Check sum)
Delimiter
Description
4
"0050"–"1000"
3
"050"–"100"
(Check
Delimiter
sum)
(Check
Delimiter
sum)
ME-LP400V-EX-6
Remarks
Remarks

Hide quick links:

Advertisement

Table of Contents