Measurement with two encoders - actual values for two encoders
Program code
N2
N3
N4
N5
N6
N7
N8
N9
7.8.2
Measuring mode 2
Supplementary conditions
● Two probes
● Trigger signals are the rising and falling edges
● Actual value from the current encoder
Program code
N2
N3
N4
N5
N6
N7
N8
N9
N10
N11
7.8.3
Continuous measurement
Supplementary conditions
● The measurement is done in measuring mode 1:
● Measurement with 100 values
● One probe
● Trigger signal is the falling edge
● Actual value from the current encoder
Extended Functions
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
MEASA[X] = (31, 1, -1) G01 X100 F100
STOPRE
IF $AC_MEA[1]==FALSE gotof ENDE
R10=$AA_MM1[X]
R11=$AA_MM2[X]
R12=$AA_MM3[X]
R13=$AA_MM4[X]
END
MEASA[X] = (2, 1, -1, 2, -2) G01 X100 F100
STOPRE
IF $AC_MEA[1]==FALSE gotof MESSTASTER2
R10=$AA_MM1[X]
R11=$AA_MM2[X]
PROBE2
IF $AC_MEA[2]==FALSE gotof ENDE
R12=$AA_MM3[X]
R13=$AA_MM4[X]
END:
M5: Measurement
7.8 Channels - only 840D sl
529