Siemens SINUMERIK Series Function Manual page 526

Extended functions
Hide thumbs Also See for SINUMERIK Series:
Table of Contents

Advertisement

M5: Measurement
7.7 Simulated measuring
Figure 7-25
The measured value is the actual value of the axis at the instant in time that the switching
signal programmed in the measuring block occurs (rising / falling edge).
If several axes are programmed in a measuring block, then a dedicated switching position is
obtained for each axis by the position offset that is axially taken into consideration. The
probe signal is generated at the first axial switching position that is reached.
Note
Probe signals
The probe signals are always simultaneously generated for probes 1 and 2.
Negative offset values
The switching position is shifted behind the end position by entering a negative value for the
position offset. In this case, no probe signals are generated.
Examples
The position offset is set to 0.1 mm: MD13231 $MN_MEAS_PROBE_OFFSET = 0.1
Example 1: Channel-specific measuring in 2 axes
Program code
N10 G01 G90
N20 MEAS=1 X100 Y10 F100
Example 2: Axial measuring using synchronized action
Program code
N10 G01 G90
N15 WHEN TRUE DO MEASA[X]=(1,1)
N20 X10 F100
526
Position-dependent switch request
Comment
;
rising edge, probe 1
;
Switching position[X] = 99.9
;
Switching position[Y] = 9.9
Comment
;
rising edge, probe 1
;
Switching position[X] = 9.9
Function Manual, 03/2013, 6FC5397-1BP40-3BA1