Basic information about the drive system
12.7 Examples of replacing components
The component has been successfully replaced
Example: Replacing a Motor Module/Power Module with a different power rating
Precondition:
The replaced power unit has a different power rating
Vector: Power rating of the Motor Module/Power Module not greater than 4 * motor current
Table 12- 13 Example: Replacing a power unit with a different power rating
•
•
•
•
•
The component has been successfully replaced
600
Action
Action
Switch off the power supply
Replace the defective
component and connect the
new one
Switch on the power supply
Drive Object CU:
–
p0009 = 1
–
p9906 = 2
–
p0009 = 0
–
p0977 = 1
Drive Object component:
–
p0201 = r0200
–
p0010 = 0
–
p0971 = 1
Reaction
Reaction
Alarm A01420
Device configuration
•
Component comparison
•
Completing the configuration
•
Data backup
•
Use the code number
•
Completing commissioning
•
Data backup
•
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
Remark
Remark
For p9906=2: Caution
Topology monitoring for all
(!) components heavily
reduced so that DRIVE-CLiQ
lines may be hidden by
mistake.
The new order number is
stored in the RAM of the
Control Unit and has to be
copied to the non-volatile
memory with p0971 or
p0977.
Drive functions