10.1 Communication according to PROFIdrive
Bit
Meaning
7
Acknowledge error
Note:
Faults are acknowledged at a 0/1 edge via BI: p2103 or BI: p2104 or BI: p2105.
8...9
Reserved
10
Control by PLC
Note:
This bit should not be set "1" until PROFIdrive has returned an appropriate status via E_ZSW_BM.9 = "1".
11...1
Reserved
4
15
Controller sign of life toggle bit
M_ADD
Supplementary torque with telegram 220 (metal industry).
M_LIM
Torque limit with telegram 220 (metal industry).
Not available in V/f control mode.
10.1.3.3

Description of status words and actual values

Description of status words and actual values
Note
This chapter describes the assignment and meaning of the process data in SINAMICS
interface mode (p2038 = 0).
The reference parameter is also specified for the relevant process data. The process data
are generally normalized in accordance with parameters p2000 to r2004.
The following scalings apply:
a temperature of 100°C = 100%
an electrical angle 90° also = 100 %.
434
Remarks
0/1
Acknowledge error
-
-
1
Control by PLC
This signal must be set so that the process data
transferred via PROFIdrive are accepted and
become effective.
0
No control by PLC
Process data transferred via PROFIdrive are
rejected - i.e. assumed to be zero.
-
-
1
Toggle bit communication active
0
Toggle bit communication not active