MT_STW
Control word for the "central probe" function. Display via r0685.
Table 10- 36 Description of MT_STW (control word for Control Unit)
Bit
Meaning
0
Falling edge probe 1
1
Falling edge probe 2
2
Falling edge probe 3
3
Falling edge probe 4
4
Falling edge probe 5
5
Falling edge probe 6
6...7
Reserved
8
Rising edge probe 1
9
Rising edge probe 2
10
Rising edge probe 3
11
Rising edge probe 4
12
Rising edge probe 5
13
Rising edge probe 6
14..
Reserved
15
CU_ZSW1 (status word of the DO1 telegram (telegrams 39x))
See function diagram [2496].
Table 10- 37 Description of CU_ZSW1 (status word of the CU)
Bit
Meaning
0
Reserved
1
Reserved
2
Reserved
3
Fault active
4
Reserved
5
Reserved
6
Ready for switching on
7
Alarm present
8
SYNC
464
Activation of measuring time determination with the next falling
edge
For telegram 392, in addition, probes 3 and 6
Activation of measuring time determination with the next rising edge
For telegram 392, in addition, probes 3 and 6
-
-
-
-
-
-
1
Drive object: Device (CU)
0
-
-
-
Central "ready for switching on" state of the drive unit
1
Device is in the "not ready for switching on" state
0
Device is in the "ready for switching on" state
1
Alarm is active
0
No warning
SYNC bit of TM17 indicates that the slave is synchronized.
1
Slave synchronized
0
Slave not synchronized
Remarks
Remarks
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
BICO
CI: p0682
BICO
-
-
-
BO: r2139.3
-
-
BO: r899.0
BO: 2139.7
BO: r0899.8