c.
Install the PE2-to-Unidrive cables as follows:
Cable
From end point PE2
CC440
Feed motor
CC441
Feed motor power orange cable
CC442
Impression engage motor
CC443
Impression engage motor power orange cable
CC422
Exit nip feed motor
CC423
Exit nip feed motor power orange cable
CC444
Turnbar feed motor
CC445
Turnbar feed motor power blue cable
9.
Install the PE1-to-PE2 cables as follows:
Cable
From end point
CC9B
Electronic gearing PE2 ESBPRO J53 connector
CC114A
PE2 service door interlock
PE1 ECN Electronic engage cable
10.
Install the PROFIBUS cables as follows:
Cable
From end point
Electrical cabinet M2 80A7
CC428
Purple
connection
To end point
Electrical cabinet M1 53A5
connection
Purple cable terminator should be
turned off
CA294-03070 rev 00
Installation Manual
To end point
FP2 encoder 26K0
FP2 drive 26K9 pins PE, PE, 2, 4, 6
IP2 encoder 27K0
IP2 drive 27K9 pins 2, 4, 6, PE, PE
FE encoder 28K0
FE drive 28K9 pins PE, PE, 2, 4, 6
FX encoder 29K0
FX drive 29K9 pins PE, PE, 2, 4, 6
To end point
PE1 ESBPRO J65 connector
PE1 service door interlock
PE2 ECN Electronic engage cable
Notes
Connection is on top of
cable CC408
page 67 of 153