Configuring networks
4.5 Configuring PROFINET IO with IRT
4.5.8

Configuring IO modules or drive telegrams

The isochronous-conform modules (e.g. input/output modules, DO or telegrams) to be
configured must be selected individually in order to make the desired settings in the
"Properties" inspector window. You can select these modules in the device view or device
overview (in the case of GSD-based devices, only in the device overview).
Requirement
● The devices to be configured have been inserted (at least one NCU and one PROFINET
IO IRT-conform device).
● The isochronous-conform modules and submodules to be configured have been inserted
in the PROFINET IO IRT-conform device.
See also Isochronous-capable modules identification (Page 86)
● The PROFINET IO IRT-conform devices are interconnected to the NCU with X150.
● The NCU is configured.
See also Configuring the NCU (Page 90)
● The device or the rack is configured.
See also Configuring PROFINET IO IRT devices (Page 92)
Procedure
To configure the inserted IO modules, select them successively and make the settings
individually for each module in the inspector window. Proceed as follows:
1. In the device view, select the rack and open the device overview.
Figure 4-5
2. In the device overview, select on the rack of the PROFINET unit one of the inserted
modules to be configured.
94
Device overview example of a GSD drive device with modules
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017, A5E41846325