Configuring the NCU
2.6 Creating SINUMERIK PLC archives
2.6.2
Available SINUMERIK archive types
There are different types of archives which you can create in different ways. Essentially, you
cannot use the TIA Portal to create archives that contain NC, drive or HMI data. However,
you can save a finely granular selection of translated program blocks as an archive in the
TIA Portal with the "PLC reload archive".
Archive type
NCU commissioning
archive
PLC commissioning
archive (Page 39)
PLC hardware upgrade
archive (Page 38)
PLC reload archive (Pa-
ge 41)
Complete archive
Original status archive
36
Command in the TIA
Command in
Portal
SINUMERIK Operate
-
Softkey "Commission-
ing archive", option
button "Create com-
missioning archive"
Hardware and all pro-
Softkey "Commission-
gram blocks...
ing archive", option
button "Create com-
missioning archive";
only enable "PLC
data" in the dialog
Only hardware...
Softkey "Commission-
ing archive", option
button "Create PLC
hardware upgrade
archive (only SDBs)"
Selected program
-
blocks...
-
<Ctrl> + <Alt> + S
-
Softkey "Commission-
ing archive", option
button "Create archive
original status"
Data contained
The contained data can be configured as
follows in the dialog:
NC data
•
–
With or without compensation data
–
With or without compile cycles
PLC data (all or none)
•
Drive data (ACX format or ASCII format)
•
HMI data (all HMI data or a configurable
•
selection)
Hardware data (SDB) of the PLC
•
Program blocks of the PLC
•
Hardware data (SDB) of the CP
•
Hardware data (SDB) of the PLC
•
Hardware data (SDB) of the CP
•
Program blocks of the PLC
•
(configurable in the dialog)
All data (not configurable)
Original status (factory setting) of all subcom-
ponents or a selection of specific subcompo-
nents and data (configurable in the dialog)
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017, A5E41846325