Safety configuration

9.3 Changing the Safety Integrated mode

EMERGENCY STOP button symbol when using Safety Integrated plus (F-PLC)
If you activate the "Safety Integrated plus (F-PLC)" mode and therefore use PROFIsafe
telegrams, all devices with fail-safe modules (PROFIsafe telegrams) have an EMERGENCY
STOP button symbol in the network and topology view:
Figure 9-2
9.3
Changing the Safety Integrated mode
Requirement
● The "SIMATIC STEP 7 Safety Advanced" option package has been installed.
Procedure
To change the Safety Integrated mode, proceed as follows:
1. Click the NCU in the network or device view and select the "Safety Integrated" entry in
the "Properties" inspector window at "General".
Figure 9-3
164
NCU with EMERGENCY STOP button symbol
Properties inspector window - Safety Integrated when using NCU V4.7
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017, A5E41846325