The Safety Integrated modes of the NCU control the safety behavior of the NCU together
with the integrated subcomponents, such as the PLC, SINAMICS Integrated and possibly
connected NX modules. Depending on the used mode and communications standard
(PROFINET or PROFIBUS), you must configure further relevant properties and F-
parameters for various modules. Sample configuring sequences can be found in Sections
Configuring Safety Integrated (SPL) (Page 177) and Configuring Safety Integrated plus (F-
PLC) (Page 192).
You can, however, also parameterize the appropriate properties in a different order.
Overview
The following table shows in which device properties and in which section you find a specific
configuration-relevant setting:
Note that not all parameters are relevant in both Safety Integrated modes. In addition, some
parameters are displayed only in a specific Safety Integrated mode for the SINAMICS
Integrated and NX components and the associated telegrams.
Table 9- 1
Setting
Safety Integrated mode
(operating mode)
Basis for PROFIsafe
addresses
F-source address
(F_Source_Add)
F-destination address
(F_Dest_Add)
DIL switching setting
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017, A5E41846325
Configuration-relevant properties
Can be found at
NCU > Safety Integrated
PLC > Fail-safe > F-parameters
PLC > Fail-safe > F-source ad-
dresses
(only for Safety Integrated mode
(SPL))
(for a GSD module, also under
"Module > PROFIsafe")
Module/submodule > F-
parameters
Module/submodule > F-
parameters
Safety configuration
9.4 Parameterization of relevant properties
Further information
This chapter, "NCU properties"
section.
Changing the Safety Integrated
mode (Page 164)
Safety Integrated mode (SPL)
Safety Integrated plus mode (F-
PLC)
Information system, keyword "Ba-
sis for PROFIsafe addresses".
Configuration of the PROFIsafe
addresses (peripherals)
Configuration of the PROFIsafe
addresses (drives)
Information system, keyword "Spe-
cial considerations when configur-
ing the F-system"
Information system, keyword "Spe-
cial considerations when configur-
ing the F-system"
Configuring Safety Integrated plus
(F-PLC) (handling overview)
Configuring Safety Integrated
(SPL) (handling overview)