Series Commissioning - Siemens SINUMERIK 840D sl Function Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

05.08
9.3

Series commissioning

The setting for the safety monitoring functions is automatically transferred with
other data in the course of a normal series commissioning process. The following
steps need to be taken in addition to the normal commissioning procedure:
1. Enter a user agreement
2. Carry out an acceptance test
(individual monitoring functions must be randomly tested)
Sequence of operations for series commissioning
The following sequence of operations is recommended when commissioning series
equipment:
S Download the data set for the series machine into the control.
S Adjust the absolute encoder.
S Carry out a power on.
This ensures that any errors – i.e. deviations in the data content that may exist
between the NCK and drive – will be detected by the checksum check and
crosswise data comparison.
Data must be checked if an error is detected. Cross check errors on the hard-
ware–related cross checksums (Alarm 27032 with ID 1) or Alarm 27035 are
normal if the series commissioning data come from another machine.
If an error is not detected, then data has not been changed and is identical to
the acceptance test data. The copy function may be used if data is subse-
quently altered.
S Carry out random function tests.
The tests are required for acceptance of the new machine.
Software/hardware upgrade
Warning
!
Please carefully read the instructions in the relevant Update Manual before
updating the software.
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Commissioning
9.3 Series commissioning
9-409