05.08
4.8

Acceptance test and acceptance report

4.8.1

General information about acceptance

Also see Chapter 9.5 of this Function Manual.
Acceptance test
The machine manufacturer must carry out an acceptance test for the activated
Safety Integrated functions (SI functions) on the machine.
During the acceptance test, all the limit values entered for the enabled SI functions
must be exceeded to check and verify that the functions are working properly.
Warning
!
The acceptance test must only be carried out after the safety functions have been
commissioned and power on reset.
SINAMICS firmware versions
For SINUMERIK software releases 1.3 and 1.4/2.4, different firmware versions of
the components involved in the safety functions (NCU, NX, Motor Modules) can be
mixed without having to adapt the firmware versions.
From SINUMERIK software release 1.5/2.5 onwards, the following applies:
The firmware versions of the Motor Modules involved in the safety functions must
be adapted to the SINAMICS firmware version of the NCU. This is performed auto-
matically during startup if parameter p9826 (firmware, automatic) is set to 1
(default setting). When Safety Integrated is used, parameter p9826 (firmware,
automatic) must be set to 1 – and must not be re–parameterized. For the accep-
tance test for Safety Integrated, the safety firmware versions of all of the Motor
Modules involved in the safety functions must be read out, logged and checked
against the following list.
http://support.automation.siemens.com/WW/view/de/28554461
Every line in the table represents a permissible combination of safety firmware ver-
sions.
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Safety Functions Integrated in the Drive
4.8 Acceptance test and acceptance report
4-79