Managing user data
12.1 User data backup
12.1
User data backup
Introduction
Data is backed up by means of the HMI. SINUMERIK solution line components can either be
backed up individually or jointly. You can select from:
• NCK (NC)
• PLC
• HMI
• Drives
12.2
User data backup/Series commissioning
Introduction
Data can be saved and archived in the following ways:
• Reading out the data completely: Series commissioning
• Files are exported/imported area by area.
In the case of a data backup, e.g., following commissioning of the control system, the user
data selected via the user interface are written to what is known as a series-commissioning
file. Once a series-commissioning file has been imported, the control system returns to its
original state, as it was at the time of the data backup.
Time of data backup
Experience has shown that the following times can be recommended for carrying out data
backups:
180
The following user data can be selected as individual files:
– Machine data
– Setting data
– Tool data
– R parameters
– Zero point offset
– Compensation data (LEC)
– Part programs
– Standard cycles
– User cycles
– PLC programs (binary file)
CNC Part 1 (NCK, PLC, drive)
Commissioning Manual, 11/2006, 6FC5397-2AP10-2BA0