Samsung DCS Programming Manual page 395

Combined systems
Hide thumbs Also See for DCS:
Table of Contents

Advertisement

SAMSUNG
COMBINED SYSTEMS PROGRAMMING MANUAL
ALM CODE
ALARM
MJB06
IPC MSGQ Over
MJB06
IPC MSGQ Under
MJB07
Task MSGQ Over
Task MSGQ Un-
MJB07
der
MJC01
DTMF Fault
MJC02
Tone Fault
MJC10
AA-DTMF Fault
MJC11
AA-MFR Rec
MJC12
E911 Restart
MJC13
E911 Block
MJC14
VoIP Restart
MJC15
VoIP Block
MJD01
Sync Failure
MJD02
Sync Recovery
MJD03
Red Alarm
MJD04
Red Alarm Rec
MJD05
Yellow Alarm
MJD06
Yellow Alarm Rec
MJD07
Blue Alarm
MJD08
Blue Alarm Rec
IPC TX queue full error has occurred in the MCP.
Alarm data = IPC Queue type
(MCP-LAN, MCP-SCP, MCP-LCP1, MCP-LCP2)
IPC TX queue under error has occurred in the MCP.
Alarm data = IPC Queue type
(MCP-LAN, MCP-SCP, MCP-LCP1, MCP-LCP2)
Task MSG queue full error has occurred in the MCP.
Alarm data = Error Task Kind
(CNFG, ERRH, NPER, MSGH, DIGH, SMART, CALL, PPER,
SMDR, TMMC, IDLE)
Task MSG queue under error has occurred in the MCP.
Alarm data = Error Task Kind
(CNFG, ERRH, NPER, MSGH, DIGH, SMART, CALL, PPER,
SMDR, TMMC, IDLE)
An abnormal interrupt has occurred in the system DTMF
resources.
Alarm data = DTMF Receiver number (BASE, MISC)
An abnormal interrupt has occurred in the system tone resources,
i.e. busy, ringback, error, no more calls etc.
Alarm data = TONE Receiver number (BASE, MISC)
An abnormal fault reported in one of the systems AA card DTMF
resources.
Alarm data = Cabinet, Slot, Port (Cx–Syy-Pzz)
An abnormal fault reported in one of the systems AA card DTMF
resources has recovered.
Alarm data = Cabinet, Slot, Port (Cx–Syy-Pzz)
The E911 card has restarted.
Alarm data = Cabinet, Slot (Cx–Syy)
The E911 card has restarted because the system detected the
card does not work correctly.
Alarm data = Cabinet, Slot (Cx–Syy)
The ITM3/MGI card has restarted.
Alarm data = Cabinet, Slot (Cx–Syy)
The ITM3/MGI card has restarted because the system detected
the card does not work correctly.
Alarm data = Cabinet, Slot (Cx–Syy)
Clocking on TEPRI cards has become asynchronous.
Clocking on TEPRI cards has become synchronous.
Locally detected loss of PCM carrier on TEPRI card for more
than 250 ms.
Alarm Data = Cabinet, Slot (Cx-Syy)
PCM carrier detected locally on TEPRI cards.
Alarm Data = Cabinet, Slot (Cx-Syy)
Remotely detected failure transmitted in frame on TEPRI card.
Alarm Data = Cabinet, Slot (Cx-Syy)
Remotely detected failure restored transmitted on TEPRI card.
Alarm Data = Cabinet, Slot (Cx-Syy)
All 1's being transmitted on facility on TEPRI card.
Alarm Data = Cabinet, Slot (Cx-Syy)
A blue alarm condition has been cleared.
Alarm Data = Cabinet, Slot (Cx-Syy)
MMC 851 (Page 3 of 5)
MMC PROGRAMS
FEBRUARY 2004
DEFINITION

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents