FOR:
Purpose: Allows certain station timer values to be changed on a per-station basis or for
all stations. You are advised not to change these values without assistance from
Technical Support.
0 NO ANS FWD
1 DTMF DUR.
2 F–DGT DELY
3 OFFHK SEL
4 EFWD DELAY
* Other systems can be programmed for these options in
Note: It is reasonable for the system administrator to use trial and error to find a suitable value for
options 1 and 2 above according to the characteristics of the selected Voice Mail system.
ACTION
1. Open programming and select 502
Display shows
2. Dial station number (e.g., 205)
OR
Press VOLUME keys to select station and press
RIGHT soft key
OR
Select all stations
3. Dial timer number from above list (e.g. 1)
OR
Press VOLUME keys to select and press RIGHT
soft key to move cursor
STATION-WIDE TIMERS
ALL SYSTEMS
Controls how long the station will ring before a Forward on No
Answer takes place. (Range: 001- 255 sec.)
Governs the duration of DTMF digit which is transmitted to an
external VM system port. It is useful for customising a voice
mail system. (Range: 100 - 9900 msec.)
Allows a suitable delay for generating DTMF digits, for com-
mencing in-band integration. (Range: 100 - 9900 msec)
Controls the grace period between lifting the handset and plac-
ing an internal/external call as programmed in
(Range: 0-250 sec) (iDCS & OS500 systems only)*
Controls how long a station set to External Call Forward will
ring before the call is forwarded. (Range: 1-250 sec) (iDCS &
OS500 systems only)*
(see section 1.5.2)
MMC 502 (Page 1 of 2)
MMC PROGRAMS
MMC
501.
DISPLAY
[201] NO ANS FWD
015 SEC →_
[205] NO ANS FWD
015 SEC →_
OR
[ALL] NO ANS FWD
015 SEC →_
[205] DTMF DUR.
0100 MS →_
FEBRUARY 2004
MMC
306.