COMBINED SYSTEMS PROGRAMMING MANUAL
MMC: 506
FOR:
Purpose: Sets and changes tone cadences on a system-wide
available, as listed below. Tones can be set to 'interrupt' or 'continuous', and interrupt
tone cadences can be customised. Some systems may require default settings to comply
with local operating companies.
FEATURE KEYS
DIAL 0
INTERRUPT TONE
DIAL 1
CONTINUOUS TONE
TONES
BUSY
CONFM/BARGE
DIAL
DND/NO MORE
ERROR
HOLD/CAMPON
MSGWAT
RGBACK
RING
TRSFER
DID RNGBACK
CO BUSY
CO RINGBACK
CO DIAL
ACTION
1. Open programming and select 506
Display shows
2. Press VOLUME keys to select tone (e.g.TRSFER)
and press RIGHT soft key
3. Dial 0 for INTERRUPT tone or 1 for CONTINUOUS
tone
OR
Press VOLUME keys to select and press RIGHT
soft key
4. If you selected INTERRUPT tone, dial in new
value(s) for interrupt times (must be four digits each
– sequence is on/off/on/off)
Press RIGHT soft key to advance cursor
Press LEFT soft key to retreat cursor
If entry is valid, system returns to step 2
ALL SYSTEMS
Busy tone
Confirm tone and Barge-in tone
Dial tone
DND tone and No More Call key tone
Error tone
Hold tone and Camp-on tone
Message waiting tone
Ringback tone
Ring over page tone (to external page port)
Transfer dial tone
AC15 ringback tone (not available on 408 systems)
CO Busy tone
CO Ringback tone
CO Dial tone
MMC 506 (Page 1 of 2)
MMC PROGRAMS
FEBRUARY 2004
TONE CADENCE
basis.
There are 14 tones
DISPLAY
BUSY TONE
INTERRUPT TONE
TRSFER TONE
INTERRUPT TONE
TRSFER TONE: 0100
0100 0100 0100